...Keep reading...
Compression Ratio:- recommended: P2/P0 = 2.5- maximum: P2/P0 = 4Mechanical life: the number of cycles is inversely proportional to the increase of the compression ratio. For pulsation dampener applications, the nitrogen value must be from 60% to 80% of the working pressure also in relation with the type of pump and the working temperature.Warranty: see dedicated page Spare parts: see dedicated pageAvailable:- Inside and outside epoxy painted as per standard FOX procedure or as project specificatio- Internal lining in different material- Bladders in HNBR, EPDM, FPM - Connection with flange SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN- Special connection on request - LT series for temperature of – 40°C - S series for separator of fluid - - Execution 310 Bar