Compression ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 6
Mechanical life: the number of cycles is inversely proportional to
the increase of the compression ratio. For pulsation dampener applications, the
nitrogen value must be from 60% to 80% of the working pressure also in relation
with the type of pump and the working temperature.
Warranty: see dedicated page
Spare parts: see dedicated page
Available :
- Outside epoxy painted as
per standard FOX procedure or as project specification
- Internal lining in
different materials
- Diaphragm in HNBR, EPDM,
FPM , HYTREL
- Connection with flange
SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN
- Special connection on request
- LT series for temperatures up to –40 °C
- M series rechargeable with
nitrogen valve M28x1.5
- V series not rechargeable with a fixed nitrogen preload in the factory
- S series for separator of fluid
- High pressure execution
- Available volumes up to
20 liters